Jet Fan for Car Parking Specification

  • Automation Grade
  • Semi-Automatic
  • Application
  • Basements, Underground Car Parks, Tunnels
  • Frequency
  • 50 Hz
  • Power Source
  • Electric
  • Accessories
  • Mounting Brackets
  • Filtration Property
  • No
  • Shape
  • Cylindrical
  • Humidity Range
  • Up to 95% RH
  • Energy Efficiency Rating
  • IE2/IE3 Motor
  • Coverage Area
  • Wide Coverage (depends on layout)
  • Air Flow Capacity
  • 6000-10000 m/h
  • Technology
  • Impulse Jet Fan Technology
  • Surface Finish
  • Powder Coated
  • Motor Speed
  • 1450 rpm
  • Noise Level
  • Below 75 dB(A)
  • Mounting Type
  • Suspended/Ceiling Mounted
  • Features
  • Low Height Design, Maintenance Free, High Thrust, Reversible Option
  • Material
  • Mild Steel
  • Type
  • Jet Fan
  • Power
  • 3.7 kW
  • Voltage
  • 415 V
  • Capacity
  • 6000-10000 m/h
  • Installation Type
  • Ceiling Mounted
  • Usage
  • Car Parking, Basement Ventilation
  • Function
  • Ventilation and Smoke Extraction
  • Direction of Air Flow
  • Uni/bi-directional
  • Control Panel
  • Optional Remote/Local
  • Weight
  • Approximately 80-120 kg (depending on model)
  • Color
  • Grey/Silver
  • Motor Protection
  • IP55
  • Blade Material
  • Aluminum Alloy
  • Thrust Force
  • 50-80 N
  • Number of Fans
  • Single/Double Impeller Option
  • Temperature Resistance
  • Up to 400°C for 2 hours (Smoke Extraction Mode)
 
 

About Jet Fan for Car Parking

Jet fans are a type of ventilation system that can be used in car parks to control and distribute air, and help with smoke control:

  • Air distribution: Jet fans can distribute air evenly throughout a space without the need for ducts.
  • Smoke control: Jet fans can be used to help firefighters by detecting the origin of a fire and controlling the spread of smoke.
  • Air mixing: Jet fans can mix air completely and dilute carbon monoxide (CO) efficiently.
  • Energy efficiency: Jet fans can be started when needed, saving energy.
  • Safety: Jet fans can be used to safely evacuate occupants in the event of a fire.
  • Jet fans can be used in underground car parks and tunnels. They are available in two types: axial and centrifugal. Axial jet fans are good for moving air over car parking spaces and driving lanes, while centrifugal jet fans are better for low ceiling areas.
  • When choosing jet fans, you can consider their thrust value, which is measured in newtons (N). Some common thrust values are 20N, 30N, 50N, 80N, and 100N




Advanced Jet Fan Technology

Our jet fan uses impulse jet technology, ideal for moving air efficiently through wide spaces like basements and underground car parks. The jet fan features aluminum alloy blades and a cylindrical, low-height design for streamlined, space-saving installation. Ceiling mounting keeps the unit unobtrusive while maximizing coverage, making it highly suitable for commercial and residential environments requiring reliable ventilation or smoke extraction.


Safety and Durability Assured

Designed for demanding conditions, this jet fan is capable of functioning at temperatures up to 400C for 2 hours in smoke extraction mode. It is built with mild steel, a powder-coated surface, and robust motor protection (IP55), ensuring exceptional durability and a long lifespan. Its maintenance-free operation, combined with reversible capability and high thrust, delivers security and peace of mind in emergencies.

FAQ's of Jet Fan for Car Parking:


Q: How is the Jet Fan installed in car parking areas or basements?

A: The jet fan is primarily ceiling mounted using included mounting brackets. Its low-height and cylindrical design allows installation in locations with height constraints, such as underground car parks and basements.

Q: What is the main function of the Jet Fan in parking lots and basements?

A: Its primary functions are ventilation and smoke extraction, ensuring that air quality is maintained and smoke is effectively removed during emergencies, thus improving occupant safety and comfort.

Q: When does the jet fan operate in high-temperature smoke extraction mode?

A: In case of fire or smoke emergencies, the jet fan automatically switches to smoke extraction mode, operating at temperatures up to 400C for two hours to ensure efficient removal of hazardous gases and smoke.

Q: Where can the Jet Fan be used besides car parking areas?

A: Aside from car parks, this jet fan is ideal for underground basements, tunnels, and other large enclosed or semi-enclosed spaces that require significant air movement or smoke control.

Q: What benefits does the reversible airflow option provide?

A: The reversible (bi-directional) airflow capability allows the fan to direct air according to specific ventilation demands, improving the flexibility and efficiency of air management within the covered area.

Q: How does the optional remote/local control panel assist in operations?

A: The optional control panel allows operators to manage the fan's operation locally or remotely, offering convenience and rapid responsiveness to changing ventilation or emergency requirements.

Tell us about your requirement